Variations of blown insulation

    
Variations of blown insulation
Climatizer Plus® Climawood® Climastyren® Climastone® L Climastone® S Climaglass® Y Climaglass® W
PROPERTIES
Material cellulose wood fibre graphite polystyrene stone mineral stone mineral glass mineral glass mineral
coefficient of thermal conductivity
λ [W/(m.K)]
0,038 0,038 0,034 0,038 0,037 0,039 0,041–0,032
specific heat capacity
c [J/(kg.K)]
2 020 2 100 1 270 900 900 840 840
density
p [kg/m3]
30 – 90 32 – 60 11 – 18 40 – 90 50 – 110 25 – 60 14 – 50
diffusion resistance factor
µ [-]
1,1 – 3 1 – 2 2 – 5 1 1 1,1 1
phase shift of the temperature oscillation 30 cm at rest [hod] 6,6 6,1 3,6 4,4 4,9 2,1 1,4
reaction to fire class C-s1, dO E E A1 A1 A1 A1
flame spread index 0,00 – 0,00 0,00 0,00 0,00 –
APPLICATIONS
insulation of horizontal cavities and beam ceilings
insulation of horizontal surfaces open blowing, trusses
insulation of pitched roofs
insulation of vertical wall structures
insulation of double-skinned roofs
floor insulation and field construction